78 A-Class Mark II
Step
Action Displayed Message Comment
G
Press the UP Key,
incrementing the Gain
Number by one, and then
press the ENTER Key.
Record the sensor reading
as a Label Value in the
table.
Repeat this step for each
of the remaining Gain
Numbers.
GAIN TRAN
*01 (0 – 31)
<yyy>
- Or, for reflective media:
GAIN REFL
*01 (0 – 31)
<yyy>
Where ‘yyy’ represents the
current sensor reading.
Sample Calibration Table
Gain Number Label Value TOF Value Difference Value
00 252
01 250
02 248
… …
31 009
Step
Action Displayed Message Comment
H
Raise the printhead
assembly then proceed
according to the media
type:
Die-cut Media –
Remove a label or two
from the liner then
position the Eye Mark
over that area.
Notched Media –
Position the Eye Mark
over the center of a
notch.
Reflective Media –
Position the Eye Mark
over the center of a
face-down black mark.
GAIN TRAN
*31 (0 – 31)
<yyy>
- Or, for reflective media:
GAIN REFL
*31 (0 – 31)
<yyy>
See Section 3.2.