I-Class 111
C) Comments – This field can be modified with no effect.
When editing has been completed, highlight all of the columns you desire to create
(more than one language may be selected) by pressing the letter above the column.
Press the Generate DPL File(s) radio button. A file will be generated for each of the
selected columns and Excel will provide confirmation. (Example: small.ls)
Download the generated files to the printer – one method is the DOS copy command:
copy small.ls lpt1: /b
Reset the printer by pressing and holding the CANCEL Key for approximately four
seconds.
Verify the operation by printing a Configuration Label (see Section 4.3.2). The new font
selection will be printed on the label under SYSTEM INFORMATION / OPTIONAL
LANGUAGES or select the new language in the SYSTEM SETTINGS / MENU LANGUAGE in
the printer’s menu.
This is the only method to determine whether the download was successful. If the menu
displays the new language selection, but all messages remain in English an error has
occurred. Re-check the process.