44 I-Class
System Settings (continued)
Menu Item Details
VOID DISTANCE
Sets the distance to print VOID on a faulted label,
where:
0.50in (10 – 2.00)
Is the distance, measured from the trailing edge, which
establishes the text size.
Note: VOID will not be printed if insufficient text
space exists or if the fault occurred after
printing completed. Also, the text can be
customized; see the Class Series 2
Programmer’s Manual.
RETRY COUNT
Sets the number of printing attempts before declaring a
fault, where:
1 (0 - 3)
Is the count.
Note: Greater than 1 (one) counts are valid only
when Linear Scanner or RFID equipped.
BACKFEED ON CLEAR
Determines positioning after a fault is cleared, where:
DISABLED
No label positioning occurs, as the location is assumed
correct.
Note: If reloading, the user must place media at the
SOP position.
ENABLED
Automatically positions the label.
SCL FONT BOLD FACTOR
Sets a scalable font boldfacing amount, where:
01 (1 – 36)
Is the setting, based on an incrementing scale where
one (01) is minimum.
4.2.6 Communications
The Communications menu contains interface port and host control functions:
Menu Item Details
SERIAL PORT A
Controls the RS-232 communications settings for Serial
Port A, where:
BAUD RATE
Sets the serial communication rate, where: